ALESIS MICROVERB 3 PDF

Ich setzte es in Verbindung mit meinem Vierspurkassettenrekorder bzw. Mein Exemplar eines Microverb II verrichtet nun seit ca. Schon das Drehen der Regler ist ein Genuss. Die Potis besitzen viele Rasterpositionen und drehen sich mit leichtem Widerstand ohne zu wackeln oder zu kratzen, sehr cool! Hergestellt wurde die Alesis Micro-Serie ab ca. Mitte der 80er Jahre.

Author:Faell Tenris
Country:Laos
Language:English (Spanish)
Genre:Business
Published (Last):9 October 2007
Pages:346
PDF File Size:5.3 Mb
ePub File Size:12.99 Mb
ISBN:840-3-30693-618-3
Downloads:73058
Price:Free* [*Free Regsitration Required]
Uploader:Kagaktilar



It is intended only for the use of those authorized by Alesis. If you are not the authorized, intended recipient, you are hereby notified that any review, dissemination, distribution or duplication of this document is strictly prohibited.

If you are not authorized, please contact Alesis and destroy all copies of this document. You may contact Alesis at servicemanuals alesis. Together with the User Reference Manual, this document provides a complete description of the functionality and serviceability of the Device. Any comments or suggestions you may have pertaining to the document are welcome and encouraged. Therefore, if you perform, or if the Manual is used to perform, any service or repairs on any Alesis product or part thereof, any and all warranties of Alesis as to that product and any service contract with Alesis for that product shall be voided and shall no longer apply for such product, even if your services or repairs were done in accordance with the Manual.

All service or repairs done by you or with reference to the Manual shall be solely your responsibility, and Alesis shall have no liability for any such repairs or service work.

All such service or repairs are performed at the sole risk of the person performing the service or repairs. You agree that all such work will be performed in a competent, professional and safe manner at all times and to indemnify and fully hold Alesis and its successors and assigns harmless in the event of any failure to so perform.

Your purchase of the Manual shall be for your own ultimate use and shall not be for purposes of resale or other transfer. As the owner of the copyright to the Manual, Alesis does not give you the right to copy the Manual, and you agree not to copy the Manual without the written authorization of Alesis.

Alesis has no obligation to provide to you any correction of, or supplement to, the Manual, or any new or superseding version thereof. Alesis shall have the right to refuse to sell or otherwise transfer repair parts or materials to you in its sole discretion. You shall not use, sell or otherwise transfer spare or replacement parts supplied by Alesis to you i to repair or be used in products manufactured for or by third parties or ii to any third parties for any purpose.

You shall not make any warranties or guarantees with respect to the products of Alesis or the use thereof on behalf of Alesis or in your own name.

The foregoing describes the entire understanding related to sale or transfer of the Manual to you, and no other terms shall apply unless in a writing signed by an authorized representative of Alesis. All Trademarks are property of their respective companies. A The arrowhead symbol on a lightning flash inside a triangle is intended to alert the user to the presence of un-insulated "dangerous voltage" within the enclosed product which may be of sufficient magnitude to constitute a risk of electric shock to persons.

A The exclamation point inside a triangle is intended to alert the user to the presence of important operating, maintenance and servicing instructions in the literature which accompanies the product. Danger of fire or electrocution if fuse is incorrectly replaced.

Replace with only the same type or equivalent type recommended by the equipment manufacturer. Danger of explosion if battery is incorrectly replaced.

Replace only with the same or equivalent type recommended by the manufacturer. Confidential Alesis Service Manual A Safety Instructions Carefully read the applicable items of the operating instructions and these safety suggestions before using this product.

Use extra care to follow the warnings written on the product itself and in the operating instructions. Keep the operating instructions and safety suggestions for reference in the future. Power Source. The product should only be connected to a power supply which is described either in the operating instructions or in markings on the product.

Power Cord Protection. AC power supply cords should be placed such that no one is likely to step on the cords and such that nothing will be placed on or against them.

Periods of Non-use. Foreign Objects and Liquids. Take care not to allow liquids to spill or objects to fall into any openings of the product. Water or Moisture. The product should not be used near any water or in moisture.

Do not place the product near heat sources such as stoves, heat registers, radiators or other heat producing equipment. When installing the product, make sure that the product has adequate ventilation. Improperly ventilating the product may cause overheating, which may damage the product. The product should only be used with a rack which the manufacturer recommends.

The combination of the product and rack should be moved carefully. Quick movements, excessive force or uneven surfaces may overturn the combination which may damage the product and rack combination. The product should only be cleaned as the manufacturer recommends.

The user should only attempt the limited service or upkeep specifically described in the operating instructions for the user. For any other service required, the product should be taken to an authorized service center as described in the operating instructions. Damage to the Product. Qualified service personnel should service the unit in certain situations including without limitation when: a.

Liquid has spilled or objects have fallen into the product, b. The product is exposed to water or excessive moisture, c. The AC power supply plug or cord is damaged, d. The product shows an inappropriate change in performance or does not operate normally, or e. The enclosure of the product has been damaged. Confidential Alesis Service Manual A 1.

These values are then mathematically manipulated, and stored at various locations in a memory "loop" for eventual playback. By varying the placement and amplitude of incoming samples, discrete time delays are achieved. When mixed together, and converted back into analog, these delays simulate the reflections associated with natural reverbs, and delays, as well as non natural effects such as reverse reverbs, and gated reverbs.

The added capabilities of an 80C31 micro controller allow for user manipulation and storage of algorithm parameters, as well as effects such as chorus, and flange, that require real-time manipulation of algorithms. Please note that there are several different board revisions, so differences will be noticed from unit to unit. Input from J7 is R. F filtered or bypassed in some units by the large torroid and C While operating the unit monauraly, the input impedance fixed at K R2, and R3, in parallel.

From there, the inputs are buffered by U1, and passed through the input potentiometers. The stereo signal is then sent to a X10 gain stage U1 etc. The summed stereo signal is sent to the anti-aliasing filter consisting of most of U4, and associated resistors and capacitors.

There are several important features in the filter to be aware of. This signal is injected into the signal path at U4 pin A signal diode at pin 10 limits the incoming signal to 5V, preventing damage to the analog switch U6. The output of U4 pin 8 has a tap running to R46, a 2N transistor, etc.

This diff-amp speeds up the response time of the comparator. At the appropriate time, the DAC will output the processed left, and right signals. After passing through low pass anti aliasing filters 2 op amps of U3, Misc. The idea is to divide the process into short, manageable sections. Each significant binary weight starting with the Most Significant Bit is taken in turn, thus requiring only 16 comparisons to achieve a final value. The process begins with the input "sample and hold" circuit.

When the switch is turned off, the capacitor will hold that level indefinitely [barring internal leakage ]. This process continues until a value is found for all 16 bits, and the data is ready for further processing by the ASIC. In order to see these signals properly on the scope, it will be necessary to use an external scope sync use U6, pin 9 as the sync source.

Note that the data buss serves a dual purpose. This buss multiplexes between low order addresses 1st 8 bits , and data. Latch U26 is used to hold the low order address half, during read and write cycles. When this circuit is functioning incorrectly, a complete lock-up of the machine, will occur. A thorough knowledge of the operation of this circuit will greatly facilitate troubleshooting this unit.

Note that the first units released did not incorporate the full reset circuit described below. Most of these early units have been retrofitted with an extra board containing the newer reset circuit. The newest board revisions incorporate the reset on the board. When the raw supply reaches approximately 7 volts, the transistor will turn on, discharging Cl 00 through R, and dropping the reset line low.

During write cycles of the , data on the data buss is made available to a series of latches U12, U22, and U Consequently, data can be "stored" into a latch simply by writing a value into a nonexistent memory location. Memory mapped input works much the same. The address lines are again decoded when A15 is active.

The can then read the data for use as necessary. This allows the to manipulate algorithms in real-time. Because the two devices operate asychronously a great deal of control logic is necessary to prevent buss conflicts.

Timing is so critical throughout this circuit that parts that are even slightly out of spec will cause failures. This is due to the fact that propagation delay times are not only significant, but inherently part of the design. If the logic seems a bit confusing at first, it helps to remember that many of the target signals are active low.

The M3 also utilizes a double buffering system to ensure smooth operation, i. At the end of the of the current sample period, the banks are switched. The "FLIP" bit is used to keep track of this.

CLEARONE SR1212 PDF

Zeitmaschine: Alesis Microverb I und II, Hallger├Ąt

.

GENERAL SMEDLEY BUTLER WAR IS A RACKET PDF

Alesis MicroVerb 3

.

LATA NAUKI WILHELMA MEISTRA PDF

All user reviews for the Alesis MicroVerb 3

.

Related Articles